CS 300 Gate Controls / Rev.D 5.6 – 15
SYSTEM
Pro-Line
7.3 Overview of the LCD monitor
ATTENTION!
Damage can occur through improper installation!
The mains power supply must be switched off before
connecting the display unit. Only an MFZ display unit
(article number 206023) may be used.
AUTOMATIC O
STANDBY
A
B
C D E
F
G
H
Key:
A: Mode of operation / Diagnostics info
B: Parameters / Diagnostics info
C: Button (+)
D: Button (–)
E: Button (P)
F: Value / Status
G: Value / Status
H: Jumper
If jumper H is removed, the (+) button, the (–) button and the
(P) button have no function.
The display still functions.
7.4 LCD monitor, modes of operation
The control has four modes of operation with the LCD moni-
tor:
1. AUTOMATIC
2. ADJUSTMENT
3. INPUT
4. DIAGNOSIS
Operating mode 1: AUTOMATIC
The door system is operated in the AUTOMATIC operating
mode.
Display:
Displays the action being carried out
Displays any error messages
If the “PRESS/REL“ parameter is set to MOD2 or MOD3 in
the input menu, the display changes from AUTOMATIC to
MANUAL.
Operating mode 2: ADJUSTMENT
ADJUSTMENT mode is used for setting the OPEN/CLOSED end
positions.
ATTENTION!
Malfunctions can occur as a result of incorrect
operation of the control!
In ADJUSTMENT mode, the door will not stop automatically
when it reaches the end position if an electronic end
position system (AWG) is used. The door can be damaged if
it is moved beyond the end position.
Fine adjustments can be made in the INPUT operating mode.
Display:
The current end position value is shown
Operating mode 3: INPUT
In the INPUT operating mode, the values of various parame-
ters can be altered.
Display:
Displays the selected parameter
Displays the programmed value / current status
Operating mode 4: DIAGNOSIS
IntheDIAGNOSISoperatingmode,door-speciccheckscan
be queried.
Display:
Displays the checks
Displays the status of the checks