EasyManua.ls Logo

Procom BLUE FLAME MNSD100TBA - Inspecting Heater

Default Icon
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.usaprocom.com
23200213-01B
1/2 Glass
Height
1/2 Glass
Height
Yellow
Tipping
1/2 Glass
Height
1/2 Glass
Height
Yellow
Tipping
INSPECTING HEATER
Figure 24 shows a correct pilot ame pattern.
Figure 25 shows an incorrect pilot ame pat-
tern. The incorrect pilot ame is not touching
the thermocouple. This will cause the ther-
mocouple to cool, which shuts the heater off.
If pilot ame pattern is incorrect, as shown
in Figure 25
turn heater off (see To Turn Off Gas to Ap-
pliance, page 20 or 21)
see Troubleshooting pages 25 through 28.
WARNING: If yellow tipping
occurs, your heater could pro-
duce increased levels of carbon
monoxide. If the burner ame
pattern shows yellow tipping,
follow instructions below.
Figure 24 - Correct Pilot Flame Pattern
Figure 25 - Incorrect Pilot Flame Pattern
Figure 26 - Correct Burner Flame Pattern Figure 27 - Incorrect Burner Flame Pattern
IMPORTANT: Owners should check pilot ame pattern and burner ame pattern often.
Incorrect ame patterns indicate the need for cleaning (see Care and Maintenance,
page 24) or service.
WARNING: Only a qualied service person should service and
repair heater. This includes maintenance requiring replacement or
alteration of components.
PILOT FLAME PATTERN
Notice: Do not mistake orange ames with
yellow tipping. Dirt or other ne particles enter
the heater and burn causing brief patches of
orange ame.
BURNER FLAME PATTERN
Figure 26 shows a correct burner ame pat-
tern. Figure 27 shows an incorrect burner
ame pattern. The incorrect burner ame
pattern shows yellow tipping of the ame. It
also shows the ame higher than 1/2 the heat
shield height.
If burner ame pattern is incorrect, as shown
in Figure 27
turn heater off (see To Turn Off Gas to Ap-
pliance, page 20 or 21)
see Troubleshooting pages 25 through 28.
NG
3-3.5" WC
Natural Gas
Shown
LP
8-11" WC
NG
3-3.5" WC
Natural Gas
Shown
LP
8-11" WC

Related product manuals