EasyManua.ls Logo

Prodys QUANTUM LITE - Page 91

Prodys QUANTUM LITE
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Prodys S.L. Tel: +34 91 6896880 Fax: +34 91 6943777 Email: sales@prodys.net Web: www.prodys.com
Page 91
active until the codec is synchronized again after rebooting. If synchronization
is not possible, the alarm will be finished.
Talkback (Codec 2) decoder framed lost: Same, but associated with
Talkback or Codec 2.
No level Detected: This alarm detects the absence of audio in input or
output. The configuration is done through Severity selection menu, in which
monitoring (input, output or both) and thresholds (minimum audio level and
waiting time) have been added.
Program (Codec 1) Decoder not framed: Active if, once the codec is
connected, the synchronization is not achieved after a time window, in
seconds, configured by the user.
Talkback (Codec 2) decoder not framed: Same, but associated to
Talkback or Codec 2.

Table of Contents

Other manuals for Prodys QUANTUM LITE

Related product manuals