Page #13 background imageLoading...
Page #13 background image
13
FAULT CODES
Error Codes may appear and these are:
Remote
LCD
Power
(Red LED)
Charging
(Blue LED)
Full
(Green LED)
Fault
Remedy
Err __ __ __
(Slow Flash)
OFF OFF Short circuit or
reverse connection
of the clips.
Check clips are not
touching each other
OR
Check the clips are
correctly connected
to the battery.
F01 – – – – – –
(Fast Flash)
OFF ON Bulk charging has
timed out and stopped
after 10 hours.
Battery may be faulty.
F02 – – – – – –
(Fast Flash)
– – – – – –
(Fast Flash)
OFF Soft Start has timed
out as the battery has
not reached 10.0V
after 2 hours.
Battery may be faulty,
check the battery or try
and charge again.
F03 – – – – – –
(Fast Flash)
ON – – – – – –
(Fast Flash)
Absorption has been
charging for more
than 20 hours and is
now in float mode.
Battery may be faulty or
there could be a load on
the battery.
CLd Battery Temp is less
then 0°C. Charging at
reduced current.
To protect the battery.
Warm the battery up.
HtC Battery Temp is greater
than 45°C the charger
voltage is reducing, to
protect the battery.
Cool the battery down.
OTP The charger has
overheated (>70°C)
and has switched off.
Ensure adequate
ventilation around the
charger.
OCP The charger has
encountered an error.
Contact Brown & Watson
International.