EasyManua.ls Logo

Proline PCI300G-E - Refrigerant and Switching On

Proline PCI300G-E
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UK - 8 -
REFRIGERANT
The refrigerating gas contained in the circuit of this appliance is Isobutene (R600a);
it causes a low level of pollution but is inflammable.
CAUTION:
Extreme caution must be used when moving the appliance.
WARNINGS:
Do not damage the refrigerant circuit.
Do not use sharp or pointed objects such as knives to remove ice when defrosting.
Do not use mechanical devices or other means to accelerate the defrosting process,
other than those recommended by the manufacturer.
Do not use electrical appliances inside the food storage compartments of the
appliance, unless they are of the type recommended by the manufacturer.
If the appliance is installed in a carpeted area, do not let the carpet block the ventilation
holes in the base of the unit, adjust the levelling feet after a few hours to compensate
for carpet movement.
Keep ventilation openings, in the appliance enclosure or the built in structure clear
of obstructions.
Switching On the Appliance
Before switching on, place the appliance in a upright position and wait at least three
hours without moving the appliance. This will give the refrigerant circuit time to settle
and operate efficiently.
Clean the appliance thoroughly, especially in the interior, before use (See Cleaning
and Maintenance).
Installation of the appliance and electrical connections must be carried out by a
qualified technician, in accordance with the Installation Manual and local regulations.
Installation into the kitchen unit is explained in the Installation Manual. This product
is intended to be used in dedicated kitchen units only.
Check that the voltage marked on the rating plate corresponds to the supply in your
area.
Their must be a dedicated 13A socket that is permanently accessible for the exclusive
use of this appliance.
Insert the plug into a socket with an efficient ground connection. If the socket has no
ground contact or the plug does not fit, we suggest you to call a qualified electrician
for assistance.
Manufacturer is not responsible for failure to complete the ground connection as
described in this booklet.
There may be an odor when you first switch on the appliance. It will disappear after
the appliance starts to cool.
PDF created with pdfFactory Pro trial version www.pdffactory.com