EasyManua.ls Logo

ProTeam PC17 - How to Change Mode; How to Set Desired Water Temperature; How to Change Parameter Setting - ONLY for DEALERS

ProTeam PC17
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
3.4 How to set the desired water temperature
1. First select the desired mode: auto, heating or cooling
2. Regardless of whether the heat pump is running or on standby, press or . The
display will show the currently set water temperature of the selected mode with a
flashing number: change the water temperature by moving or as required
3.5 How to change parameter setting - ONLY FOR DEALERS
1. In standby status, press and hold MODE button for 5s, then use or to find
parameters 0-A and measured values of current status B or F, both parameter and
value will be blinking.
2. Press and hold and at the same time for 5 seconds continuously to activate
parameter setting
3. Change value on setting until a BEEP is heard while display continues to indicate
parameters by means of flashing values
4. Wait for 5 seconds to store the data automatically and return to standby status. Press
button to start the heat pump working.
Check if the heat pump is in required mode- auto, cooling, heating.

Table of Contents