Maintenance / Disposal
18 OPTIMAX
®
®
2.31. Repeat item 2.20 to 2.30 if required (observe information e. g. concerning temperature, time and cleaning pro-
cedure outlined in tank cleaner datasheet)
2.32. Remove roller racks from the machine and remove dirt under flowing water using a soft rag or sponge
2.33. Remove residual dirt particles in tanks and rinsing gutters.
2.34. Clean all toothed gear wheels, axles, bearings and rollers, check them for damage (replace if required)
2.35. Remove light protection flap and wipe its underside using a soft rag
2.36. Clean inlet plate using a soft rag
2.37. Reinstall light protection flap
2.38. Align roller racks and re-insert them in machine
2.39. Fill machine with chemicals
2.40. Switch machine on
2.41. Adjust bath temperature to previously adjusted value
2.42. Feed cleaning film (approx. 4 pieces)
2.43. Check function as described under item 1.
2.44. Approx. 15 minutes after reaching of the set bath temperature, measure it for confirmation and re-calibrate if
required (see operating manual page 39)
2.45. Perform sensitometric test
Please dispose of all old devices in an environmentally
friendly manner.
Old devices contain materials which need to be recycled. Please
have them collected separately and recycle appropriately.