Trouble Shooting
26 OPTIMAX
®
®
Trouble Shooting
Summary
1 Algae ............................................................................................................ 26
1.1 Excessive algae growth in water tank.................................................... 26
2 General......................................................................................................... 27
2.1 Machine has no power........................................................................... 27
3 Drive .............................................................................................................27
3.1 Filmfeed out of order, dryer-fan is working ............................................ 27
3.2 Machine does not start automatically .................................................... 27
3.3 Machine doesn't stop automatically....................................................... 27
3.4 Drive motor does not run .......................................................................27
3.5 Transport stops before film comes out, changing the cycle time........... 27
3.6 Processing time and developer temperature relation ............................ 28
3.7 Changing the transport speed ............................................................... 28
4 Bath ..............................................................................................................28
4.1 No circulation in bath ............................................................................. 28
4.2 Developer temperature too high ............................................................ 28
4.3 Developer temperature too low.............................................................. 29
4.4 Developer temperature too low, fixer temperature too high................... 29
4.5 Removing the turning knob.................................................................... 29
4.6 Calibration of developer temperature .................................................... 29
5 Film defects ................................................................................................. 29
5.1 Films will not dry .................................................................................... 29
5.2 The film does not transport correctly ..................................................... 29
5.3 Scratches, pressure marks, dirt on film ................................................. 29
6 Replenishment ............................................................................................ 30
6.1 Replenishment pump does not pump or does not pump sufficiently ..... 30
6.2 Replenishment rates are too high or too low ......................................... 30
6.3 Adjust replenishment pump ................................................................... 30
7 Dryer............................................................................................................. 30
7.1 Dryer fan does not function or runs with reduced speed ....................... 30
8 Water ............................................................................................................30
8.1 Rinsing water does not flow................................................................... 30
8.2 Water tank overflows ............................................................................. 30
1Algae
1.1 Excessive algae growth in water tank
Algae growth inside the water tank is not only anoying, it causes increased
cleaning work and leaves residue on the films. When algae is present, correc-
tive measures are required:
When work has been completed at the end of the day, drain water out of the
machine.
Clean dryer-water rack regularly. Use soft sponge and soap to remove resi-
due from the rollers.
Install a particle filter system in the fresh water supply for the processor.
If water tank overflows due to algae growth blocking the overflow hose, then
the overflow hose can be attached directly to the connection at the water tank
inside the machine.
If no other solutions can be found, then usage of Anti-Algae-Agents can be a
great improvement (automatic dispensers work the best). However, it is
known that cleaning agents containing chlorine may corrode rubber rollers
and high-grade steel in the tank area (check before use).