EasyManua.ls Logo

Proton SLR mini 3060 - OUTPUT PARAMETERS

Default Icon
127 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 114 of 126
Proton Products SL mini and SLR mini Series Speed and Length Gauges Instruction Manual - issue 1s
OUTPUT PARAMETERS
1 DW word = 2 bytes 2013.08.26
DW
Bit
Comments
Units
Range/Remark
0
0
Mode
0=Normal
1=Batch
1
Length / speed resolution
0=Length 0.1 / speed 0.01
1=Length 0.0001 / speed
0.001
2
Not used
3
Measured length >= Preset1
1=>Preset
4
Measured length >= Preset2
1=>Preset
5
Length reset
0=Reset
6
Measurement unit
0=Metres
1=Feet
2=Yards
3=other unit (set on PCIS)
7
8
Speed signal output response
0=Averaged
1=Instantaneous
9
10
Laser status
1=Laser on
0=Laser off
11
Gauge OK
1=Gauge OK
12
Speed reading validity
1=Valid
0=Invalid
13
Object detected
1=Object detected
0=No object
14
Good reading status
1=Lower than threshold
0=OK
15
Not used
1
0
Gauge OK
1=Error
0=OK
1
Laser temperature too high
1=Too high
0=OK
2
Laser temperature too low
1=Too low
0=OK
3
APD temperature too high
1=Too high
0=OK
4
APD temperature too low
1=Too low
0=OK
5
APD DC level
1=Too high
0=OK
6
Gauge too hot
1=Too hot
0=OK
7
Not used
8
Not used
2
Average speed
Old format: 1=0.01m/min {ft/min} {yds/min}
New format: 1=0.001m/min{ft/min}{yds/min}
±10~999999
(0.10~9999.99)
3
4
Instant speed
±10~999999
(0.10~9999.99)
5
6
Total length / Batch length (when in
batch mode)
Old format: 1=0.1m{ft}{yds}{inch}
New format: 1=0.0001m{ft}{yds}{inch}
±200,000.0000
7
8
Logic input
0
Not used
1
Direction
0=Count up
1=Count down
2
Logic input 1 function
0=Direction
1=Length hold
2=Display hold
3=Speed hold
3
4
Logic input 1 state
1=Active
5~7
8
Logic input 2 function
0=Reset input
1=Length hold
9
10
Logic input 2 state
1=Active
11
Direction
0=Count up
1=Count down
12
Length hold
1=Hold
13
Display hold
1=Hold
14
Speed hold
1=Hold

Table of Contents

Related product manuals