Proton Products SL mini and SLR mini Series Speed and Length Gauges Instruction Manual - issue 1s
SL / SLR gauge configuration via RS232:
The following input parameters can be programmed via RS232 (and other optionally installed
interfaces) on the SL / SLR gauge. For further information regarding the data format for programming
parameters, please consult the SL / SLR gauge instruction manual.
DW
Data
bit
Comments
Value
12
0
Logic input 1 function
1= Length hold
1
2
3
Logic input 1 polarity
0 = active low (pulled down)
4
Logic input 2 function
1 = Length hold
5
6
7
Logic input 2 polarity
0 = active low (pulled down)
8
Logic input 3 function
4= Reset length [if signal held for 5s, resets reel number]
9
10
11
Logic input 3 polarity
0 = active low (pull-down)
DW
Comments
Unit
Range
Value
14
Length offset
1=0.1m{ft}{yds}{inch}
3000.0~3000.0m{ft}{yds}{inch}
Set to distance “L”
SL mini / SLR mini configuration
Configuration via the PCiS_SLmini software:
1
Click the “Interface” button on the main page:

Table of Contents