Proton Products SL mini and SLR mini Series Speed and Length Gauges Instruction Manual - issue 1s
In quadrature mode, “Pulse output 1and “Pulse output 2” run at the same pulse rate (set as
the “Pulse 1 rate”) with a 90° phase shift between the two outputs:
Pulse outputs electrical specifications
Specification
Minimum
Typical
Maximum
Units
Pulse output external power supply (POUT +V)
+5
+25
VDC
Pulse output frequency
2*
MHz
* reduced with increasing cable length in accordance with RS-422 standards.
P1A or P2A
/P1A or /P2A
P1A
/P1A
P2A
/P2A

Table of Contents