Proton Products SL mini and SLR mini Series Speed and Length Gauges Instruction Manual - issue 1s
Label
Value
Description
PROFI ID
0 ~ 125
Enter the PROFIBUS ID (address) assigned to the gauge.
Configuration via input parameters:
This interface may be configured by writing to the following input parameters:
Input parameters:
DW
Bit
Comment
Unit
Range/Remark
Default
20
Profibus address
1=1
0~125
7
ETHERNET / IP OR PROFINET COMMUNICATIONS
The EtherNet / IP or PROFINET interface is an optional extra that must be ordered for
installation during manufacture; it cannot be retrofitted to the gauge.
The Ethernet/IP interface is compatible with PLCs fitted with an Ethernet/IP interface that supports the
CIP (Common Industrial Protocol).
This communications interface operates independently of the other communications interfaces and
may be used at the same time as them.
EtherNet / IP or PROFINET interface
The EtherNet / IP or PROFINET interface may be accessed through the following pins:
Connector type: DB25 female (socket)
Functional
group
Pin
Designation
Description
Notes
Shield
S
Shield
Shield
Connect to cable and plug shields
Ethernet/IP or
PROFINET
Industrial bus
22
IBUS1
TX+
10
IBUS2
TX-
23
IBUS3
RX+
11
IBUS4
RX-
1
14
2
15
3
16
4
17
5
18
6
19
7
20
8
21
9
22
10
23
11
24
12
25
13