Windows IAS RADIUS Server Configuration
Tsunami MP-8100 Reference Manual 88
10. At this point, you must add Vendor Specific values. Click Add to enter Proxim’s vendor code values. The RADIUS
Attributes window is displayed.
a. Select Vendor Specific RADIUS Standard. The Multivalued Attribute Information window is displayed.
b. Click Add to get Vendor Specific Attribute Information.
c. Select the Specify Network Access Server Vendor radio button and enter 841 for Proxim code.
d. Click Yes. It conforms the radio button under Specify whether the attribute conforms to RADIUS RFC
specification for vendor specific Attributes area.
e. Click Configure Attribute to display the Configure USA (RFC Compliant) values window.
f. In the Vendor Assigned Attribute number area, select either (1) for Input/Uplink or (2) for Output/Downlink.
g. For Attribute Format, select Decimal.
h. For Attribute value, select the Kbps value being tested, for example 64 for 64Kbps.
i. Click OK to save configuration.
j. Click Apply to RADIUS Attributes configuration.
k. Click OK. The following window is displayed:
Your configuration should be complete.
5.1 Addition of Units to a Routed Network
The following describes how additional units can be added to a routed network:
1. Log into the BSU by placing its IP address into a Web browser address field.
2. When the Web interface is displayed, click the Web Config button.