Event Log Error Messages
Tsunami MP-8100 Reference Manual 81
3.15 Wireless
Error Type Message Description Corrective Action
CRITICAL Security Profile 'Selected
Name' doesn't Exist
Security Profile selected in
association with current wireless
configuration does not exist.
Check your configuration
and try again to commit
the changes.
CRITICAL Security Profile 'Selected
Name' Validation Failed
Security Profile configured is not
valid.
Check your configuration
and try again to commit
the changes.
CRITICAL Security Profile 'Selected
Name' Flash Commit Failed
Changes made to the security
profile were not saved and will
not come into effect.
Reboot the device and try
again.
ALERT Security Profile 'Selected
Name' is Disabled - No Security
Configuration is Applied
No security profile is enabled
and the network is unsecured.
NONE
CRITICAL Security Profile Invalid
Encryption Type for Selected
Security Mode
The encryption type selected for
the security mode is not valid.
Check your configuration
and try again to commit
the changes.
CRITICAL WORP: WEP Encryption
Key(KeyLength) not valid
WEP encryption key length is
not valid.
Check your configuration
and try again to commit
the changes.
CRITICAL WORP: TKIP Encryption
Key(KeyLength) not valid
TKIP encryption key length is not
valid.
Check your configuration
and try again to commit
the changes.
CRITICAL
WORP: AES-CCM Encryption
Key(KeyLength) not valid
AES-CCM Encryption key length
is not valid.
Check your configuration
and try again to commit
the changes.
CRITICAL Security Profile: Security Mode
Invalid
Security Mode selected is not
valid.
Check your configuration
and try again to commit
the changes.
CRITICAL
Radius Server Profile Name
Doesn't Exist
Radius Server chosen for the
wireless configuration does not
exist.
Check your configuration
and try again to commit
the changes.
CRITICAL
Primary/Secondary Auth
Servers are Inactive
Either Primary or Secondary
Authentication Servers are
inactive.
NONE
CRITICAL Radius Server IP Address is not
Valid
Radius Server IP address
configured is not valid.
Check your configuration
and try again to commit
the changes.
CRITICAL Unable to Create Security
Profile Configuration File
Security Profile changes will not
come into affect.
Reboot the device and
reconfigure.