XY View
The XY View function is used to facilitate the centering of the laser beam on the two sensALIGN
sensor detector planes before proceeding with measurement.
1) Tap the detector area shown to directly access the XY View screen.
2) The XY View screen may be accessed indirectly using the menu item "XY View" which appears
when the "sensor/laser area is tapped.
3) The XY View screen may be accessed indirectly using the menu item "XY View" which appears
when the laser is tapped.
The two sensor detector planes are displayed on the XY View screen. Center the laser beam dots in
both planes using both beam position thumbwheels. In some cases it may be necessary to move
sensALIGN sensor along the support posts or sideways by loosening the chain type bracket and
slightly rotating it.
The "Set to zero" function may be used to check the effect of environmental and machinery vibration
on the measurement. Note that the "Set to zero" is active only when the laser beam status [1] is "OK"
or "Centered".