10. SELECTION CRITERIA (COMBINED WOOD/ELECTRIC FURNACE)
RESIDENTIAL AREA
House including: basement, first floor and second floor (half)
Floor area * New house Existing house
1100 square feet or less PSG 2000 – 15KW PSG 2000 – 18 or 20KW
1100 to 1450 square feet PSG 3000 – 18KW PSG 3000 – 20 or 25KW
1400 to 2000 square feet PSG 4000 – 20KW PSG 4000(G-12)– 25 or 30KW
2000 to 3000 square feet PSG 4500 – 25KW PSG 4500 – 30KW
COMMERCIAL AREA
Building including: Walls 14 to 16 feet high
Garage doors, no basement
Floor area
2500 to 3800 square feet PSG 4500- 25 or 30KW
4000 to 10000 square feet PSG 5000 – 40, 50 or 60KW
* Consider main floor only.