ChapTEr 1: prE-INSTallaTION
3
Specications
Power Supply:
Input Voltage: 24 VAC – 40 VA or 24 VDC – 2.5 A
Current Consumption: 250 mA Maximum
Output Voltage: 14 VDC – 2 A
Relay Outputs (resistive load):
Maximum Switching Voltage: 30 VAC/DC
Maximum Switching Current: AC: 10 A (NO) / 3 A (NC)
DC: 5 A (NO) / 3 A (NC)
Maximum Switching Capacity: 1250 VA 150 W (NO)
375 VA 90 W (NC)
Minimum Permissible Load: 10 mA at 5 VDC
Contact Resistance: 100 mΩ Maximum
Life Expectancy: (at maximum rated load)
Mechanical: 10,000,000 operations
Electrical: 200,000 operations minimum
Inputs:
Dry Contact Type ONLY. Do Not apply voltage to any of the inputs.
Dry Contact Specications:
Contact Resistance: 500 mΩ Maximum
Current Capacity: 100 mA at 5 VDC Minimum
Environmental:
Ambient Temperature: -40°C to +80°C (-40°F to 176°F)
Ambient Humidity: 0% to 100% (see note)
Note: The humidity inside the housing for any controller or AI Device cannot
exceed 85% and must be noncondensing.
See the Appendix for System Requirements for computers,
components, and peripherals used with the controller.