26
- Are EXIT SENSOR & EJT SENSOR normal?
- Is LOCKING device in GUIDE CASH FEED 7 ASS’Y
locked normally?
- Is idle roller rotation status in GUIDE CASH FEED 7 ASSY
normal?
Check
Point
- Overflow bill
- JAM at EXIT Sensor or EJT Sensor
- Counting Error(between DIV Sensor and EJT Sensor)
- Counting Error(between EJT Sensor and EXIT Sensor)
- Timeout(From DIV Sensor to EJT Sensor)
Meaning
- Try again after checking above situation.
- Replace ASS’Y in case of roller rotation problem in GUIDE
CASH FEED 7 ASS’Y.
Action
34H, 35H, 3CH, 3DH, 43HCODE