EasyManua.ls Logo

PVR EU 105/B - User Manual

PVR EU 105/B
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EU 105 - EU 105/B
Lubricated vane
vacuum pump
Operating and maintenance
instructions
EN
TRANSLATION
Publication Number:
LI 2246.03 January 2020

Questions and Answers

  • J
    Jason BergAug 8, 2025
    What to do if the motor protection is tripping on my PVR Water Pump?
    • K
      Kylie AcostaAug 8, 2025
      If your PVR Water Pump's motor protection is tripping, it could be due to several reasons. It may be caused by pump seizure and jam, requiring a pump overhaul. Another possible cause is a broken vane, which means you should replace the vanes. Inefficient exhaust filters can also cause this problem, so replace them. Finally, high temperature due to polluted oil can cause the motor protection to trip, so you should change the oil.
  • P
    Peter RodriguezAug 12, 2025
    Why is there a drop in performance in my PVR EU 105/B Water Pump?
    • E
      Evan ClaytonAug 12, 2025
      If you notice a drop in performance in your PVR Water Pump, several factors could be the cause. The inlet filters might be dirty, in which case you should clean or replace them. A blocked oil cooler can also lead to reduced performance, so clean or replace it. Lack of lubrication can also be the cause, so fill the pump with oil to the correct level, or change the oil and oil filter. Lastly, a worn coupling element can lead to performance issues, so replace it if necessary.
  • S
    stewartmelissaAug 16, 2025
    How to fix an oil leak in my PVR EU 105/B?
    • C
      christopherfullerAug 16, 2025
      If your PVR Water Pump is leaking oil, there are several potential causes. The oil filling/discharge plugs might be leaking; check that the plug has been closed properly or replace the gasket. An inefficient oil recovery system could also be the cause, so check and clean the oil recovery pipe. Blocked exhaust filters can also lead to oil leaks, so replace them. Additionally, check the oil level.
  • A
    Angelica FullerAug 21, 2025
    Why is my PVR EU 105/B Water Pump discharging oil mist?
    • G
      Gwendolyn RomeroAug 21, 2025
      If your PVR Water Pump is producing discharge oil mist, it could be due to a high operating temperature caused by a high ambient temperature. To resolve this, decrease the room temperature by allowing better air exchange. Also, check that the inlet valve is tight.
  • I
    iandersonAug 26, 2025
    What causes oil to be found in the inlet circuit of my PVR Water Pump?
    • G
      gloriaschwartzAug 26, 2025
      If you find oil in the inlet circuit of your PVR Water Pump, it's likely due to an inefficient inlet valve. Try cleaning the valve and replace any damaged parts.
  • J
    Jennifer SwansonAug 29, 2025
    What causes anomalous noise in my PVR EU 105/B Water Pump?
    • A
      alejandromcguireAug 29, 2025
      If your PVR Water Pump is making anomalous noises, it could be due to several reasons. The motor or pump bearings might be damaged, requiring replacement. Damaged vanes can also cause unusual noises, so replace them. Damaged contact surfaces may be the issue, requiring a pump overhaul at our workshop. Finally, worn shaft oil seal rings can cause noise, so replace the oil seal rings.
  • M
    Michael BarberSep 2, 2025
    How to fix leaking inlet pipes on a PVR EU 105/B?
    • A
      Ashley ThompsonSep 2, 2025
      If the inlet pipes or the machine of your PVR Water Pump are leaking, identify the leaking point and seal it. Also, check the oil level and oil conditions.

PVR EU 105/B Specifications

General IconGeneral
Voltage230V
Frequency50 Hz
Maximum liquid temperature60 °C
Inlet connection1"
Outlet connection1"

Related product manuals