PVL 25 - PVL 25/B
PVL 35 - PVL 35/B
Lubricated vane
vacuum pump
Operating and maintenance
instructions
EN
TRANSLATION
Publication Number:
LI 770.03 January 2020

Questions and Answers

  • P
    Phillip FlowersAug 13, 2025
    Why is my PVR PVL 25/B motor protection tripping?
    • P
      Pamela KleinAug 13, 2025
      The motor protection may be tripping due to a pump seizure and jam, which requires a pump overhaul. Alternatively, it could be caused by a broken vane, in which case you should replace the vanes.
  • W
    William SullivanAug 17, 2025
    What causes oil leak in PVR PVL 25/B?
    • N
      Nicholas DanielAug 17, 2025
      An oil leak could be caused by blocked exhaust filters, which means you should replace the oil separator (pos.45). It can also happen due to no lubrication, in which case the oil level needs filling up.
  • B
    Bruce WilliamsAug 20, 2025
    What to do if PVR PVL 25/B has drop in performances?
    • C
      Carlos KingAug 20, 2025
      If your PVR Water Pump's performance is dropping, first eliminate any leaks. Also, check the oil level and conditions. If there's a lack of lubrication, fill with oil to the right level or replace the oil. If there is no lubrication see the previous point. Finally, a worn coupling element could be the cause, requiring a replacement.
  • P
    petersensaraAug 25, 2025
    How to fix anomalous noise in PVR PVL 25/B Water Pump?
    • B
      bethwhiteAug 25, 2025
      Anomalous noise in your PVR Water Pump can be due to several reasons: damaged motor or pump bearings (replace them), damaged vanes (replace them), or damaged contact surfaces (requires a pump overhaul at our workshop). It also might be caused by worn shaft oil seal rings, which you should replace (pos.14-15).
  • S
    strujilloAug 28, 2025
    What causes discharge oil mist in PVR Water Pump?
    • D
      Dr. Amanda BirdAug 28, 2025
      Discharge oil mist can be caused by several issues: an inefficient oil separator (check and clean the oil recovery pipe, or replace oil separator (pos.45) if the oil recovery system or exhaust filters are inefficient or blocked), no lubrication (oil level filling up), pump seizure and jam (pump overhaul), or a broken vane (replace vanes).
  • P
    pperezSep 1, 2025
    How to deal with high temperature due to polluted oil in PVR PVL 25/B Water Pump?
    • R
      robinsonrobertSep 1, 2025
      If your PVR Water Pump is experiencing high temperature due to polluted oil, perform an oil change.
  • A
    Aimee HunterSep 5, 2025
    How to reduce high operating temperature due to high ambient temperature in PVR PVL 25/B?
    • L
      Laura FaulknerSep 5, 2025
      To decrease high operating temperature in your PVR Water Pump caused by high ambient temperature, decrease the room temperature by allowing a better air exchange.
  • J
    Jordan HallSep 8, 2025
    How to clean dirty inlet filter in PVR Water Pump?
    • C
      Carol BakerSep 8, 2025
      If the inlet filter of your PVR Water Pump is dirty, clean or replace it.

PVR PVL 25/B Specifications

General IconGeneral
Power0.25 HP
Maximum Head25 m
Outlet Diameter1 inch
Frequency50 Hz
Inlet Size1 inch
MaterialCast Iron
Voltage220V
PhaseSingle