Questions and Answers

  • M
    Micheal GrahamAug 9, 2025
    What to do if my PVR Water Pump discharges oil mist?
    • B
      Brandon GreenAug 9, 2025
      If your PVR Water Pump is discharging oil mist, this could be due to several reasons. The oil separator might be inefficient, or the oil recovery system or exhaust filters could be blocked, in which case you should replace the oil separator. It may also be caused by lack of lubrication, pump seizure/jam, or a broken vane. In the first case ensure oil level filling up. In the second and third cases the pump overhaul or vanes replacement is required.
  • I
    iclarkAug 14, 2025
    Why is there a drop in performance in my PVR PVL 401 - PVL 401/B?
    • P
      Philip OrtizAug 14, 2025
      A drop in performance of your PVR Water Pump can be caused by several factors. You might have leaks in the inlet pipe or on the machine, which you should eliminate. Another cause could be a lack of lubrication, so check the oil level and condition, and fill with oil to the correct level or replace the oil. Finally, a worn coupling element can also cause performance issues, so consider replacing it.
  • K
    Kevin LewisAug 19, 2025
    What to do if the motor protection is tripping on my PVR Water Pump?
    • D
      Dale SerranoAug 20, 2025
      If the motor protection is tripping on your PVR Water Pump, it could be due to a pump seizure and jam, requiring a pump overhaul. Another potential cause is a broken vane, in which case you should replace the vanes.
  • B
    brookegarrettAug 25, 2025
    Why is my PVR PVL 401 - PVL 401/B making an anomalous noise?
    • O
      ocantuAug 25, 2025
      An anomalous noise in your PVR Water Pump may be caused by damaged motor or pump bearings, damaged vanes, or damaged contact surfaces. In the first two cases replacement is required. In the third case pump overhaul at our workshop is required. Worn shaft oil seal rings can also be the cause, so replace the oil seal ring.
  • S
    Stephanie LongAug 29, 2025
    Why is my PVR Water Pump leaking oil?
    • J
      Judith DelgadoAug 29, 2025
      If your PVR Water Pump is leaking oil, it could be due to blocked exhaust filters, in which case you should replace the oil separator. It may also be caused by a lack of lubrication, so ensure the oil level is filled up.
  • D
    David MorganSep 3, 2025
    What to do if PVR PVL 401 - PVL 401/B experiences high temperature due to polluted oil?
    • D
      Deborah HowellSep 4, 2025
      If your PVR Water Pump experiences high temperature due to polluted oil, perform an oil change.