Pompa per vuoto
Vacuum pump
EU 205 - EU 205/B
I GB
s.r.l.
pompe per vuoto
Modello
- Type
LI 1586.00 01/04
EU 300 - EU 300/B
MANUALE PER L'USO E MANUTENZIONE
OPERATING AND MAINTENANCE INSTRUCTIONS
Question and Answer IconNeed help?

Do you have a question about the PVR EU 205 and is the answer not in the manual?

Summary

1 GENERAL INFORMATION

1.1 General Information

Provides essential information for correct pump operation and ordinary servicing for safety and preventing improper use.

2 PRODUCT SPECIFICATIONS

2.1 Pump Description

Details the rotary vane vacuum pumps, their capacity, lubrication, and cooling system features.

2.2 Expected Use

Specifies the intended applications for the pumps, including vacuum ranges and operating temperatures.

2.3 Forbidden Use

Outlines prohibited uses, such as sucking liquids or dangerous gases, and installation in explosive environments.

2.4 Protections

Details necessary protections against dust, liquids, and advice on pressure switches for automatic stop.

2.5 Accessories

Lists useful accessories available for pump installation and operation, such as filters and gauges.

2.6 Overall Dimensions and Principal Parts

Presents diagrams showing pump dimensions and identifies key components with their respective labels.

2.7 Technical Characteristics

Provides detailed technical specifications including capacity, vacuum, motor power, sound level, and oil data.

3 SAFETY RULES

Hot Surfaces

Warns about high pump surface temperatures and the need for protection to avoid burns.

Harmful Substances Emissions

Addresses oil mist in discharge air and proper disposal of used oil according to regulations.

Hazard Caused by Depression

Advises against contact with the pump inlet port during operation and the need to introduce air before interventions.

Hazard Caused by Pressure

Warns that the pump tank is pressurized and advises against opening plugs during operation.

For Safe Maintenance

Stresses that maintenance must be performed by skilled personnel with the pump stopped and properly isolated.

Electric Safety

Highlights risks from live electrical parts and mandates skilled personnel for connections, complying with standards.

Fire Hazard

Warns about fire risks due to improper use or lack of maintenance and specifies appropriate extinguishers.

4 TRANSPORT;HANDLING

4.1 Lifting

Instructs on proper lifting procedures using designated eyebolts and suitable equipment for pump weight.

4.2 Unpacking and Components Control

Guides on checking the packing for damages upon receipt and inspecting pump components.

4.3 Storage

Provides guidelines for storing the pump without oil, protected from atmospheric agents within a specific temperature range.

5 INSTALLATION AND OPERATION

5.1 Assembly

Details the assembly process, including motor installation and checking coupling alignment.

5.2 Operating Vacuum Range Changing

Explains how to adjust the manual selector switch to change the pump's working vacuum range.

5.3 Location

Specifies requirements for pump installation location, emphasizing protection, accessibility, and ventilation.

5.4 Connection to the Using Machine

Guides on connecting the pump to the chamber using pipes of the same diameter and flexible fittings.

5.5 Discharge Air Pipe Line Installation

Provides instructions for piping discharge air, including maximum length and ensuring a descending slope.

5.6 Electric Connection

Details electrical connection requirements, including compliance with standards and checking motor rotation direction.

5.7 Commissioning

Outlines the procedure for initial pump commissioning, including oil filling and level checks.

5.8 Suggestion for the Use

Offers advice on operating the pump, including pre-heating at low temperatures and avoiding frequent stop-starting.

5.9 Water Vapour Suction

Explains how to handle water vapour suction, including pre-operation heating and post-operation running.

6 SERVICING

6.1 General Information

General precautions before maintenance, and a table of periodic servicing operations for pump efficiency.

6.2 Oil Change

Provides a step-by-step guide for changing the pump's lubricating oil, including safety precautions.

6.3 Coupling Elastic Element Replacement

Details the procedure for replacing the elastic coupling element, emphasizing safety during motor removal.

6.4 Exhaust Filters Replacement

Explains how to replace dirty exhaust filters to prevent overheating and potential oil ignition.

6.5 Pump Overhaul

Recommends contacting the service center for pump overhaul, involving complete disassembly and part replacement.

6.6 Spares Necessary for Normal Servicing

Identifies essential spare parts for regular maintenance, marked with 'R' and 'G' in the exploded view list.

6.7 How to Order Spare Parts

Instructs on the necessary information to provide when ordering spare parts for the pump.

7 LUBRICANTS

8 DE-COMMISSIONING

9 RETURN FOR REPAIR

10 OPERATING TROUBLES TABLE

PVR EU 205 Specifications

General IconGeneral
ModelPVR EU 205
Power200 W
Frequency50 Hz
Inlet/Outlet Size1 inch
CategoryWater Pump
Voltage230 V