15. DEFAULT SETTINGS AND MEMORY ERROR (Err)
The device has a built-in feature that allows for restoring default settings.
To use this option, PX282 must be disconnected from the power supply. Before restoring the
power, press and hold the „previous” button. After turning the device on, the message will
appear on the screen (when turning on the power until displaying the previous message,
the „previous” button must be pressed).
This menu designation restores default settings. Accepting this message by pressing the „enter”
key restores default settings. It is also possible to exit this menu without returning to default
settings by pressing the „escape” button.
źThe default settings in PX282 are as follows:
ź DMX address - 1,
ź driver operating mode - RGB (3b - 3-byte),
ź master mode - off,
ź number of sent DMX channels - 128,
ź white balance - off
ź no signal operating mode - Program 1
ź smooth function - off
13
The device is equipped with a built-in memory work control function.
If there are problems with the memory operation, on the PX282 display the Err message appears
- memory error.
In this situation, select the enter button. The device will reload the default configuration and
upload it to the memory. If after this operation, the message remains on the screen, the
memory is permanently damaged and the unit must be sent to the service point.
_
Err message - memory error
ENTER
POWER ON
PREVIOUSPRESSED
ESCAPE
16. EXCEEDING THE MAXIMUM LOAD
Driver has built-in protection against exceeding the permissible load of 6 A per channel. In the
case of exceeding the permissible load on the display starts to display a flashing sign r when the
load is exceeded on the R(red), G for channel G(green) and b for channel B(blue).
Starting from firmware version 2.03 there has been introduced an update that any overload or
short circuit on the output channel causes channel shut down and than a slow and smooth
transition to a previously predetermined value. The result of this is achieving of maximum at this
output (the channel to which might be connected e.g. LEDs) in about 15-20 seconds.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PXM PiXiMo 18 and is the answer not in the manual?

PXM PiXiMo 18 Specifications

General IconGeneral
BrandPXM
ModelPiXiMo 18
CategoryController
LanguageEnglish

Related product manuals