31/34
charged. Solution: every 3 month should do the balancing maintenance (charge to full),
normally it will been done automatically by the communication between system and external
device.
5.3.5 Output Relay Inspection:
[Periodical Maintenance] Under low load condition (low current), control the output relay OFF
and ON to hear the relay has click voice, that’s mean this relay can off and on normally.
5.3.6 History Inspection:
[Periodical Maintenance] Analysis the history record to check has accident (alarm and
protection) or not, and analysis its reason.
5.3.7 Shutdown and Maintenance:
[Periodical Maintenance]
Some system function must be maintenance during the EMS restart, it is recommended to
maintenance the system every 6 months.
5.3.8 Recycle
NOTE
Damaged batteries may leak electrolyte or produce flammable gas.
In case a damaged battery needs recycling, it shall follow the local recycling regulation (ie.
Regulation (EC) 1013/2006 among European Union) to process, and using the best available
techniques to achieve a relevant recycling efficiency.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pylontech Force-H2 and is the answer not in the manual?

Pylontech Force-H2 Specifications

General IconGeneral
Nominal Capacity3.55 kWh
Battery TypeLithium Iron Phosphate (LiFePO4)
CommunicationCAN, RS485
CertificationCE, UN38.3, IEC62619
Warranty10 years
Operating Temperature Range-10°C to 50°C
Storage Temperature Range-20°C to 60°C
IP RatingIP20
Cycle Life>6000 cycles