7
Basic Parameters
UF5000
Nominal
Voltage (VDC) 51.2
Nominal
Capacity (Wh) 5120
Usable Capacity (Wh) 4864
Depth of discharge (%)
95
Dimensions (mm)
442(W) x 452.6 (D) x 161(H)
Weight (Kg)
42
Discharge
Voltage (VDC)
45.6 ~ 56.8
Charge Voltage (VDC) 56 ~ 56.8
Recommended
Charge/Discharge Current (A)
*
100
Maximum continuous
Charge/Discharge Current (A)
*
100
Peak Charge/Discharge Current (A)
105 ~ 119 @15 minutes
120 ~ 200 @15 seconds
Communication
RS485, CAN
Configuration (maximum quantity
in one battery group)
20
Working Temperature(°C )
**
-10 ~ 55 Charge
-10 ~ 55 Discharge
Storage Temperature (°C)
-20 ~ 60
Short current/duration time (A/1ms)
< 2,000
Cooling type Natural
Protective class
I
IP rating of enclosure IP20
Humidity(%, RH, No Condensation)
5 ~ 95
Altitude(m) ≤4000
Certifications
IEC62619, UN38.3, RoHS, Reach,
WEEE, EMC/CE
Design life (year) (25°C /77
)
15
Cycle
Life (25°C /77)
> 6,000
* The maximum continuous operation current is recommended for a battery cell temperature
within 10~40°C. Exceeding this temperature range will result in lower operation current.
**
In high(>40) or low temperature (<10) environments, the charging and discharging power
of the battery system will be limited due to BMS operation logic.
Operation Cycle Life is defined based on specific operation conditions. For more details, please
consult check with Pylontech service team.