Rins171 Issue 6          Page 21 
11.8  Setting Entry Time 
To set the required Entry time.    Enter   
followed by the time required in seconds (
  to   seconds) followed by   to accept.   
Incorrect entry gives an audible error tone and correct entry gives three bleeps.  
The Entry time is factory set to 30 seconds. 
 
11.9  Setting Exit Time 
To set the required Exit time     Enter 
 
followed by the time required in seconds (
  to   seconds) followed by   to accept.   
Incorrect entry gives an audible error tone and correct entry gives three bleeps. 
The Exit time is factory set to 30 seconds. 
 
11.10  Changing the Engineer Code 
Enter 
 then   the old Engineer Code    - gives an audible acceptance tone 
    (Factory Set at 9999) 
   then 
 the new Engineer Code  - gives an audible acceptance tone 
   then 
 the new Engineer Code again- gives an audible acceptance tone 
If an incorrect key is entered an error tone will be given and the function ended. 
 
11.11 Programmable Options 
11.11.1  Programmable Output 1 
Enter 
  followed by   -     for following options: 
      0  OFF (programmable output 1 not used). 
   1 PIR remote LED enable. 
      2  PIR latch memory.  
   3 Output switch 5 secs. 
      4  Output switch reflecting Setting and disarming of panel. 
      5  Follow zone. Refer to 11.1121 for Zone allocation. 
   6 Follow line fail. 
   7 Follow kiss off. 
 
11.11.2  Programmable Output 2 
Enter 
 followed by   -     for following options: 
      0  OFF (programmable output 2 not used). 
   1 PIR remote LED enable. 
      2  PIR latch memory.  
   3 Output switch 5 secs. 
      4  Output switch reflecting Setting and disarming of panel. 
      5  Follow zone.  Refer to 11.11.22  for Zone allocation. 
   6 Follow line fail. 
   7 Follow kiss off.