Rins171 Issue 6          Page 7 
6  DIAL OUT REPORTING 
 
The Atlas 8 has the capability to send messages of alarm status to a Central Receiving Station.  Every time the alarm 
status changes i.e. Alarm Set / Unset System Fault or Alarm Actuation a message is sent to the CRS informing it of the 
status change. This is called Dial Out Reporting.  Dial Out Reporting can be configured to Group Reporting which allows 
different alarm status changes to be reported to two different  locations, 4 groups are available: 
  Group 1 - Alarms 
  Group 2 - Set / Unset 
  Group 3 - Maintenance 
  Group 4 - 24 Hour call test 
This gives the engineer the ability to configure the system to only report condition changes to relevant locations. 
i.e. one location could be informed of all status changes (Groups 1 to 4) while a second location could only be informed 
of Group 1 conditions. 
 
Confirmed Alarm: This is an extra code which is sent upon two different zones being activated in one set period.  It is 
used to signal that the alarm condition is less likely to be a false alarm, thereby resulting in a higher level of response.
 
 
7 FUNCTIONS  
 
Volume Control  This is only accessible when the front cover has been removed and will only affect the volume of any 
    extension speakers. The volume control is overridden when the panel is in an alarm state. 
 
Chime  Chime function applies to ‘day’ mode only and if selected will cause the panel to generate a three-note  
sound when an entry/exit zone is triggered. This feature is to inform the occupants of the building that 
some one has entered. 
 
Event Log  The Atlas 8 control panel incorporates a memory log of the last 30 alarm events and is accessible to 
both Users and the Engineer. It will record Fire, Intruder, Personal Attack and Tamper alarms and also 
show if any of the 8 alarm zones have been triggered or omitted. The Engineer can set the clearing of 
the log for either Engineer-only or Master User and Engineer. 
 
Auto Re-Set  After an alarm the panel will automatically reset itself when the bell timer has expired.  
    Any zones, which still remain triggered at that time, will be omitted automatically.  
 
Walk test  The walk test function allows each of the Set modes to be checked in order to verify that all the  
    intruder detectors on the alarm system are functioning correctly. When undergoing a walk test the  
    Engineer or Master User can choose which of the Set-modes he wishes to test. Any zones used in 
    that Set-mode will cause a chime at the RKP or extension speaker if they are triggered. 
 
Keypress Timeout   
There is a 60 second keypress timeout facility. If a key is not pressed within 60 seconds of the last 
  keypress the keypress buffer is cleared. 
 
Duress  This feature allows the user to either Set or Unset the alarm with the last two digits of the code  
    reversed, this will then send a Duress Code to the Central Receiving Station. 
    The panel will appear normal when the duress code is active. 
Programmable 
 
Outputs (PGM)  There are 2 programmable outputs which may be programmed for any of the following 7 options: 
 
    Remote LED Enable: This option will allow the PIR LEDs to be enabled during Walk test mode if they 
    have been originally disabled by removing the link pin. This option will only work if the PIR has a  
remote LED enable facility. 
 
    Latch Memory: This feature is useful when more than one detector is connected to a single zone.   
    When the panel is set the LEDs of any triggered detector on this zone will latch causing their LEDs 
    to flash on and off when the panel is disarmed. This feature will only work if the PIR has a Latch  
Memory facility. 
 
    5 Seconds Switch Output: This option will allow the programmable output to act as a momentary 
    switch. This could be used for example to unlock an external electronic door. 
 
    Panel Set / Unset Switch Output: By using this option the programmable output will switch as the  
    panel is set and disarmed. This may be used for example to electronically lock a door as the panel is  
set and unlock it when the panel is unset. 
 
    Follow Zone: This option will allow the programmable output to switch on and off as the  
    programmed zone is entered and exited. 
 
    Follow Line Fail: This option will allow the programmable output to switch on when a line fail  
    occurs and switch off when the line is active again. 
 
    Follow Kiss Off: This option will allow the programmable output to switch on for a few seconds  
    when a communication kiss off has been successfully completed.