Page 8 
 
 
System Option 1. The system may be configured for use with the following: 
 
    Double Pole Zones:  This is a normally closed zone configuration without end of line resistor. 
 
    Double End of Line Zones: This configuration uses end of line resistors which allow both zone and  
          tamper circuits on the same zone connection. 
    User Log Reset Enable:  This option allows the user to reset the system log by entering 
 
 
    User Log Reset Disable:  By selecting this option only the engineer has the ability to reset the system  
log. 
 
    Tone Dial:    Select this option for telephone exchanges using tone dial technology. 
 
    Pulse Dial:    Select this option for telephone exchanges using pulse dial technology. 
 
    Internal & External Sounders 
    On Tamper Activation:  This option will cause both internal and external sounders to activate on 
          a tamper alarm when the panel is in day mode. 
    Internal Sounder Only On  
    Tamper Activation:  This option will cause only the internal sounder to activate upon a tamper 
          alarm when the panel is in day mode. 
 
System Option 2. The system may be configured for use with the following: 
 
    7 Day Test Dial:    Dials the Central Monitoring Station every 7 days. 
 
    24 Hour Test Dial:  Dials the Central Monitoring Station every 24 hours. 
 
Dial In:      This option will allow the Atlas 8 to respond to an incoming call in answer  
machine compatible mode. 
 
Answer machine compatible mode: This provides a way of using the Atlas 
on the same line as an answering machine. The default setting is AMC on. 
To remotely access the Atlas in AMC mode dial in and wait for a single 
ring, then hang up and wait for at least 10 seconds, but no more than 40, 
then dial back in. The Atlas will now answer instantly. 
 
    No Dial In:    This option will cause the Atlas 8 to ignore incoming calls. The master user  
may generate a one hour time window to allow up/downloading by using  
the function. If this option is selected - this will answer on a single ring. 
   
Wide handshake filters: Gives a greater chance of the handshake from central station being 
recognised, use only if the panel does not transmit data after the correct 
handshake sequence has been transmitted by the central station.  
 
  Standard handshake   This setting is the default and will more reliably detect the correct  
   filters:    handshake 
    
 
    Silent P.A. Zones:  The P.A. zone activation will not generate internal or external sounders if  
this option is selected. Dial out will occur however if the panel has been  
     programmed to do so. 
 
    Audible P.A. Zones:  The Personal Attack zone activation will cause both internal and external 
          sounders to operate. Dial out will also occur if the panel has been  
programmed to do so. 
 
System Option 3. The system may be configured for use with the following: 
 
    Engineer Code Lock  
    N.V.M Reset:    This option allows the control panel programmable settings to be reverted  
back to factory default when in Engineer mode only. 
 
    Engineer Power Up  
    N.V.M Reset:    This allows the control panel programmable settings to be reverted back to 
     factory default when in User Mode.