No Input Types
Operation
0 Unused
Factory default. Input is disabled.
1 Fire Active at all times. Audible Response: Differentiated Internal sound. Pulsed external
sound. Communicator: ‘Fire’ signal
2 Gas Active at all times. Audible Response: Full external + Internal sound.
Communicator: ‘Gas’ signal
3 PA
#
Active at all times. Audible Response: Differentiated Internal sound. Full external
sound. Communicator: ‘Personal Attack’ and ‘Input PA’ signals
4 Silent PA
#
Active at all times. Audible Response: None
Communicator: ‘Personal Attack’ and ‘Input PA’ signals
5 Tamper When disarmed: Audible Response: Internal only. Communicator: ‘Tamper’ signal.
When armed: Audible Response: Full external + Internal sound. Communicator:
‘Tamper’ signal.
6 Instant Active when armed: Audible Response: Full external + Internal sound.
Communicator: ‘Burglary’ signal
7 Entry Delay1
#$
Active when armed: Initiates 'Entry Timer 1' when door open. If system not disarmed
before entry time expires then: Audible Response: Full External + Internal sound.
Communicator: ‘Burglary’ signal. NOTE: See type 43 for Entry Delay2
8 Follow
$
Active when armed, except during entry time. (Acts as an instant input if an Entry
Delay input hasn’t been activated beforehand).
Audible Response: Full external + Internal sound.
Communicator: ‘Burglary’ signal.
11 Push To Arm Active during exit time, to complete arming procedure. No audible or communicator
response. Panel will communicate a final armed event once the Push to Arm button has
been pressed.
NOTE: May be used to act as ‘doorbell’ by use of ‘chime’ input attribute.
Example: Wire the Door Bell button to the input. Enable “Push to Arm” option from
“EXIT MODES”, add a “Push to Arm” input type to the input and enable the “Chime”
attribute for it.
Enter user code, the panel starts arming. Exit the building and close the door. Press the
Bell button. The system will arm. If pressing the Bell button while the panel is in any
other condition the Chime will sound.
12 Switcher Active at all times in armed and disarmed modes. No audible or communication
alarms will be created. When activated it can trigger the associated output for switching
external equipment. If the “Special Log” attribute is enabled for this input an SMS
message will be sent each time the input is activated.
Example: This kind of input type can be used to control CCTV. The concept is that when
a switcher input type is activated, there is an output associated with it following that
input (the most used solution is the use of output type – 0035). The switcher input is
connected to a detector located next to a CCTV camera and the output is connected to
video recording / transmitting equipment. If the detector is activated in armed or
disarmed mode then the recording or transmission will start.
13 24 Hour When armed: Audible Response: Full External + Internal sound;
Communicator: ‘24hr Alarm’ signal.
When disarmed: Audible Response: Full External + Internal sound;
Communicator: ‘24hr Alarm’ signal if enabled in “Alarm Responses” menu.
16 Fault Active when armed or disarmed: Audible Response: internal sounder.
Communicator: Fault event.
If armed only: Activates ‘Global Fault 1’ output type.
If disarmed or armed: Activates ‘Global Fault 2’ output type.
Note that the ‘Technical Fault’ output type is triggered every time a fault is active
including when the fault input type is active.
17 Arming Control Active during arming procedure: No audible or communicator response.
Prevents system being armed whilst the input is in an active state.
18 Shunt Active at all times: No audible or communicator response.