5
ENFORCER V11 INSTALLATION GUIDE
SPECIFICATION AND WARRANTY
TECHNICAL SPECIFICATION
ELECTRICAL
European rated voltage 230V AC -15/+10%
European rated current 83mA
Capable operating voltage 90 - 264V AC
Current 222mA - 75mA
Rated frequency 50/60Hz
Zone fuse rating T 2A (cannot replace)
PSU Type A
Radio frequency 868MHz, FM Transceiver Narrow Band
ENFORCER BATTERY
Output instant voltage 11V (with no mains and battery fully charged)
Peak to peak ripple voltage 10mVpk
Battery low voltage cut o value 8.5V
Type NiMH 8 cell 2200mAh rechargeable battery
CIE current when operating on battery backup 90mA
ENVIRONMENT
Physical dimensions (W x H x D) 220 x 160 x 50mm
Weight 1025g
Operating temperature -10°C to +40°C
Nominal temperature -10°C to +50°C
Storage temperature -20°C to +60°C
I/O BOARD IF CONNECTED
Zones 2 Wired (DEOL, SEOL)
Output voltage 13.2 VDC (nominal)
Max current for PGM output 70mA
SAB outputs 250mA Continuous Load
Bus fuse F500mA 250V Bus Fuse
Aux fuse F500mA 250V Aux Fuse
SYSTEMS ANALYSIS: ZONES MAX 66
Wireless 32
Wired 2
Zone expansion modules
4 wired (8 wired zones each)
EURO-ZEM8, EURO-ZEM8+ or EURO-ZEM8+PSU
1 wireless (32 wireless zones)
EURO-ZEM32-WE