[ Table 2-3 : Basic Specifications (Germany) ]
2.3.3 Basic Specifications (Germany)
09 I Safety
Grid Connection Data (AC)
Battery Data (DC)
PV Generator Data (DC)
Max. input total power
Max. input power per string
Max. input voltage
Min. input voltage / Initial input voltage
MPPT voltage range
Max. input current per string
Number of independent MPPT trackers
Battery nominal capacity
Usable capacity
DOD (Depth of Discharge) Range
Battery voltage range / nominal voltage
Max. discharge current
Max. charge current
Battery DC/DC converter data
Max. charge power
Max. discharge power
Technology
Rated power (at 230V, 50Hz)
Max. output apparent AC power
Max. current
Nominal AC voltage / range
Rated power frequency / range
6.6 kWp
3.3 kWp
550 V
125 V / 150 V per string
125 V ~ 500 V
15 A per string
2
1 Battery Pack
4.0 kWh
3.6 kWh
4.0 kWh x Pack
3.6 kWh x Pack
2 or more Battery Pack
4.6 kW
4.6 kVA
25 A
230 V / 184 Vac ~ 264 Vac
50 Hz / 47.5 Hz ~ 51.5 Hz
9.8 A 17 A
90 %
176.4 Vdc ~ 225.12 Vdc / 203.84 Vdc
17 A
3.0 kW
Non-Isolated
2.0 kW 3.0 kW

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Q CELLS Q.SAVE G2 4kWh B1.1.1 and is the answer not in the manual?

Q CELLS Q.SAVE G2 4kWh B1.1.1 Specifications

General IconGeneral
BrandQ CELLS
ModelQ.SAVE G2 4kWh B1.1.1
CategoryInverter
LanguageEnglish

Related product manuals