80
3. Configure remote failure
Command
Explanation
Port mode
ethernet-oam remote-failure
no ethernet-oam remote-failure
Enable remote failure detection of EFM OAM
(failure means critical-event or link-fault event of
the local), no command disables the function.
(optional)
ethernet-oam errored-symbol-period
threshold high {high-symbols | none}
no ethernet-oam errored-symbol-
period threshold high
Configure the high threshold of errored symbol
period event, no command restores the default
value. (optional)
ethernet-oam errored-frame-period
threshold high {high-frames | none}
no ethernet-oam errored-frame-period
threshold high
Configure the high threshold of errored frame
period event, no command restores the default
value. (optional)
ethernet-oam errored-frame threshold
high {high-frames | none}
no ethernet-oam errored-frame
threshold high
Configure the high threshold of errored frame
event, no command restores the default value.
(optional)
ethernet-oam errored-frame-seconds
threshold high {high-frame-seconds |
none}
no ethernet-oam errored-frame-
seconds threshold high
Configure the high threshold of errored frame
seconds event, no command restores the default
value. (optional)