Page #16 background imageLoading...
Page #16 background image
16 7033-362C 11/21
Start the rst inspection after the rst 2 months of use,
or if performance changes, and adjust your schedule
accordingly. Maintenance is required for safe operation and
must be performed to maintain your warranty.
3 Maintenance and Service
A. Quick Reference Maintenance Guide
CAUTION!
Allow the appliance to completely cool down before
performing any cleaning or maintenance.
FREQUENCY TASK
Baffl e & Blanket
MONTHLY
or after every
one (1) cord of
wood
Baffl e and blanket placement is critical to heat output, effi ciency and
overall life of the appliance. Make sure the baffl e is pushed all of the
way to the back of the rebox and the blanket is laying at. Inspect
baffl e for cracks.
Ceramic Blanket
Back of Firebox
Baffle Board
Baffle Retainer
Bracket
Chimney System
EVERY TWO
MONTHS
or after every
four (4) cords of
wood
The chimney and chimney cap must be inspected for soot and
creosote every two months during the burn season or more frequency
if chimney exceeds or is under 14-16 ft (4.3m-4.8m) measured from
bottom of appliance.
This will prevent pipe blockage, poor draft, and chimney res.
Always burn dry wood to help prevent cap blockage and creosote
build-up.
Firebrick & Ash Removal
WEEKLY
or after every 25
loads of wood
Ashes must be cool before you can dispose of the ashes in a non-
combustible container.
Firebrick is designed to protect your rebox. After ashes are removed,
inspect the rebrick and replace rebricks that are crumbling, cracked
or broken.
Door & Glass Assemblies
WEEKLY
or after every 25
loads of wood
Keep door and glass gasket in good shape to maintain good burn.
To test: place a dollar bill between the appliance and door and then
shut the door. If you can pull the dollar out, remove one washer from
door handle behind latch cam and try again. If you can still pull it out,
replace the door gasket.
Check the glass frame for loose screws to prevent air leakage.
Check glass for cracks.
Door Handles
WEEKLY
or after every 25
loads of wood
Check the door latch for proper adjustment. This is very important
especially after the door rope has formed to the appliance face.
Check door handle for smooth cam operation.
These are generic drawings and may not represent your model.
Table 16.1
All manuals and user guides at all-guides.com

Other manuals for Quadra-Fire 3100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quadra-Fire 3100 Series and is the answer not in the manual?

Quadra-Fire 3100 Series Specifications

General IconGeneral
EPA CertifiedYes
Flue Size6 inches
Efficiency78%
Firebox Size2.0 cu ft
Log Length18 inches
Depth26.5 inches
Maximum Burn Time10 hours