5. Ash Removal System Inspection & Cleaning
Frequency: Monthly or after burning 50 bags
By: Homeowner
a. Be sure the appliance is allowed to cool.
b. Open the front cast door and cycle the ash removal
handle - these should be inspected for functionality
c. Inspect for any degradation or deformation.
As the springs heat up and cool down they can
lose tension
If there is a gap showing above the re pot
bottom, approximately 1/16 inch (1.59mm)
or more, it means the springs have lost their
tension
Lost tension cannot keep the oor in the
proper position causing ignition problems and
fuel falling into the ash pan. If noted, call your
dealer to replace the springs.
6. Cleaning the Hopper
Frequency: See chart on page 14
By: Homeowner
a. Be sure the appliance is allowed to cool.
b. After burning approximately 1 ton of fuel you will
need to clean the hopper to prevent sawdust and/or
nes build-up.
c. A combination of sawdust/nes and pellets on the
auger reduces the amount of fuel supply to the re
pot.
d. This can result in nuisance shut downs and mis-
starts
Empty the hopper of any remaining pellets.
Vacuum the hopper and feed tube.
Figure 17.1
Ash Dump Lever
WARNING
Risk of re!
Do NOT store fuel:
Closer than required clearances to
combustibles to appliance.
Within space required for loading or ash
removal
7. Cleaning the Glass
Frequency: See chart on page 14
By: Homeowner
a. Be sure the appliance is allowed to cool.
b. Clean glass with a non-abrasive commercially
available cleaner. Wipe down with dry towel.
8. Door Latch & Gasket Inspection
Frequency: See chart on page 14
By: Homeowner
The door latch is non-adjustable but the gasket between
the glass and rebox should be inspected periodically to
make sure there is a good seal. If the gasket is frayed or
damaged, replace with a new one.
Handle glass assembly with care when
cleaning glass door:
Avoid striking, scratching or slamming
glass.
Do NOT clean glass when hot.
Do NOT use abrasive cleaners.
Use a hard water deposit glass
cleaner on white lm.
Refer to maintenance instructions.
CAUTION
Handle glass doors with care.
Inspect the gasket to ensure it is
undamaged.
Do NOT strike, slam or scratch glass.
Do NOT operate appliance with glass
door removed, cracked, broken or
scratched.
WARNING

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quadra-Fire TREKKER INSERT series and is the answer not in the manual?

Quadra-Fire TREKKER INSERT series Specifications

General IconGeneral
BrandQuadra-Fire
ModelTREKKER INSERT series
CategoryPellet stove
LanguageEnglish

Related product manuals