Initializing the Storage Arrays and Software
Quantum DXi6900 Installation Guide 54
Probing for array 1 CTRL B: Found.
-Get Storage Info-
-Get Tray Info-
-Get Controllers Info-
-Get Drives Info-
-Get EBODs Info-
-Found EBOD 0-
Probing for array 2 CTRL A: Not Found.
Probing for array 2 CTRL B: Not Found.
Detecting -end-
Done. Output in /opt/DXi/hwdetect/factory.config
2. On the Pick to Order Menu, type the number option for Check Hardware and press <Enter>.
The Pick To Order Hardware Check Menu displays (see Figure 45 below).
Figure 45: PTO: Hardware Check Menu
*** Pick to Order Hardware Check Menu ***
0) Check Memory - check memory size to number of trays.
1) Check NetApp Trays - check for valid tray combinations.
2) Check HBAs - check for valid PCI slots and cards.
3. On the Hardware Check Menu, type the option for Check Memory and press <Enter>.
The system displays information about the installed memory (see Figure 46 below).
Make sure the memory configuration is valid before continuing (see on page 2). If the memory
configuration is not correct, resolve the issue before continuing (see Troubleshooting on page 80).
Figure 46: PTO: Check Memory
Detected Memory size: 129024 MB, (128 GB)
Memory size OK for the attached 2 tray(s) of external storage.
4. On the Hardware Check Menu, type the option for Check NetApp Trays and press <Enter>.