19617 6404: Simple release status not returned to host when persistent reserve present on target.
19816 841772
837614
6404: IOB Reboot Reason ExcHnd - Exception Occured in Interrup Contextt
19834 839406
841132
6404: Blade can reset by Watchdog Timer if many obj timeouts occur consecutively.
19872 Build script fails to deliver vxworks image when binserv is not available.
19948 Write buffer cmd with FCP_DL=0 never returns status to host.
20019 SRR offset is not used to resend data, LSI request for max data fails.
20150 836594 SCSI status lost on SRR for partial block read causes command timeout.
20343 Write buffer cmd with FCP_DL=0 never returns status to host.
20387 Report Luns command used during device discovery does not clear last 2 bytes of CDB.
20388 RES stress test with binary data compare fails.
71100 786790
786650
During upgrade, a RAS ticket is produced: Top Reach assembly of the picker robotics operation
has Failed.
71285 765442 If auto inventory is enabled, the library should not actually scan the library barcode labels on
IES or IESWR command.
71289 Picker rotates into the motor during get hunt recovery.
71347 777004
790778
The library should be able to infer which media type a magazine is if it finds barcodes in a
spot where it did not find a barcode for a magazine
71375 765442 Need to change the error E_GRP_SLOT_FULL from sev 1 to sev 3
71400 A drive unload failure should not produce a RAS event.
71480 841132 StatusMonitor process fails during blade swaps
71507 SNMP is no longer updating SANMgr tables after blade swap .
71549 809384 Need to change the error E_GRP_PROF_STORAGE_GET_SLOW_EMPTY from Critical to
Warning
71630 Drive brick firmware auto-update settings are being reset by the MCB after an auto-update.
71686 Library hangs and/or RAS tickets appear for kernel oops and out of memory errors.
71693 Remote GUI hung while getting snapshot.
71720 Heavy library scsi stress and library snapshot caused kernel 'OOPS'
71726 LLM process killed on overnight multi-initiator stress test, all SCSI commands rejected with
44/00 asc/ascq.
71731 Library doesn't respond to RES request - failed two stability libraries
71762 VCM looping on an aborted SCSI command slows the library down.
Change
Request
Number
Service
Request
Number
Description

Other manuals for Quantum Scalar i2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i2000 and is the answer not in the manual?

Quantum Scalar i2000 Specifications

General IconGeneral
BrandQuantum
ModelScalar i2000
CategoryStorage
LanguageEnglish

Related product manuals