BC95_AT_Commands_Manual Confidential / Released 53 / 58
6 Error Values
The error codes listed below are not implemented, and only a subset will be implemented.
In B600 and later, the +CMEE command is implemented and supports modes 0 & 1. In mode 1 a limited
set of error codes are returned.
Error codes are aligned to the 3GPP spec. Refer to 3GPP TS 27.007 V13.5.0, sub-clause 9.2 for all
possible <err> values. The error codes listed are those returned for the Hi2110 implementation.
Error codes 0-255 are reserved and defined in 3GPP TS 27.007 and may be used by Neul in future
releases.
Table 3: Error Values
Error Code
Error Text
3
Operation not allowed
4
Operation not supported
23
Memory failure
32
Flow control
50
Incorrect parameters
159
Uplink busy
256
Required parameter not configured