NB-IoT Module Series
BC95 AT Commands Manual
BC95_AT_Commands_Manual Confidential / Released 12 / 58
Parameter
Example
AT+CGMR
V100R100C10B650SP6
OK
AT+CGMR=?
OK
Neul Hi2110 Implementation
<revision> will change format over time. It should be treated as an opaque identifier.
3.4. AT+CGSN Request Product Serial Number
Execution command returns the IMEI (International Mobile station Equipment Identity number) and
related information. For a TA which does not support <snt>, only OK is returned. Refer to Chapter 6 for
possible <err> values.
<revision> The total number of characters, including line terminators, in the information text
shall not exceed 2048 characters. Text shall not contain the sequence 0<CR> or
OK<CR>
AT+CGSN Request Product Serial Number
Execute Command
AT+CGSN[=<snt>]
Response
When <snt>=0 (or omitted) and command successful:
<sn>
When <snt>=1 and command successful:
+CGSN: <imei>
When <snt>=2 and command successful:
+CGSN: <imeisv>
When <snt>=3 and command successful:
+CGSN: <svn>
OK
+CME ERROR: <err>
Quectel
Confidential

Table of Contents

Other manuals for Quectel BC95

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quectel BC95 and is the answer not in the manual?

Quectel BC95 Specifications

General IconGeneral
BrandQuectel
ModelBC95
CategoryControl Unit
LanguageEnglish

Related product manuals