EasyManuals Logo

Quectel EC200U Series User Manual

Quectel EC200U Series
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #86 background imageLoading...
Page #86 background image
LTE Standard Module Series
EC200U_Series_Hardware_Design 81 / 94
Table 51: EC200U-AU Conducted RF Receiving Sensitivity
Frequency
Receiving Sensitivity (Typ.)
3GPP
Primary
GSM850
TBD
-102.0 dBm
EGSM900
TBD
-102.0 dBm
DCS1800
TBD
-102.0 dBm
PCS1900
TBD
-102.0 dBm
LTE-FDD B1 (10 MHz)
TBD
-96.3 dBm
LTE-FDD B2 (10 MHz)
TBD
-94.3 dBm
LTE-FDD B3 (10 MHz)
TBD
-93.3 dBm
LTE-FDD B4 (10 MHz)
TBD
-96.3 dBm
LTE-FDD B5 (10 MHz)
TBD
-94.3 dBm
LTE-FDD B7 (10 MHz)
TBD
-94.3 dBm
LTE-FDD B8 (10 MHz)
TBD
-93.3 dBm
LTE-FDD B28 (10 MHz)
TBD
-94.8 dBm
LTE-FDD B66 (10 MHz)
TBD
-96.3 dBm
LTE-TDD B38 (10 MHz)
TBD
-96.3 dBm
LTE-TDD B40 (10 MHz)
TBD
-96.3 dBm
LTE-TDD B41 (10 MHz)
TBD
-94.3 dBm
5.7. ESD
If the static electricity generated by various ways discharges to the module, the module maybe damaged
to a certain extent. Thus, please take proper ESD countermeasures and handling methods. For example,
wearing anti-static gloves during the development, production, assembly and testing of the module;
adding ESD protective components to the ESD sensitive interfaces and points in the product design.
The following table shows the module electrostatics discharge characteristics.

Table of Contents

Other manuals for Quectel EC200U Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quectel EC200U Series and is the answer not in the manual?

Quectel EC200U Series Specifications

General IconGeneral
BrandQuectel
ModelEC200U Series
CategoryControl Unit
LanguageEnglish

Related product manuals