INSTRUCTIONS
A17™ AREA LIGHT INSTALLATION


A 1 7 S l i p t t e r
A17 Universal Pole
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.



WARNING: Make certain power is OFF before installing or maintaining  xture. No user serviceable parts inside.
WARNING: Do not use an electric generator to test LED  xtures.
WARNING: Min 75°C SUPPLY CONDUCTORS.
Suitable for wet locations.


1. Remove the Arm CoveArmArm
Cover Screws
 Arm.
 ArmArm and
tighten securely to housing.
 Arm CoverScrews
Arm
Screws
Arm Cover
Arm
FIG. 1
FIG. 2
FIG. 3
FIG. 4
Square Pole Mount
1. Place the Bolster Plate inside the Pole 
2. Remove the Round Pole Adaptor Plate.
  Arm to Square PoleBolt.
 Arm Cover
 Pole to connect to the Arm.

enclosure (Fig. 7).
 Pole.
Round Pole Mount
1. Place the Bolster Plate inside the Pole 
2. Arm to Round Pole Bolt.
3. Arm Cover
4. Pole to connect to the Arm.

enclosure (Fig. 7).
5. Pole.
Pole
Bolster Plate
Bolt
Pole
Arm
Round Pole
Adaptor Plate
Arm Cover
Note: See Pole Drilling Pattern Detail (Fig. 8).
Question and Answer IconNeed help?

Do you have a question about the RAB A17 and is the answer not in the manual?

Summary

Important Safety and Installation Guidelines

Warnings and Compliance

Covers critical warnings, NEC compliance, grounding, and qualified installer requirements.

Pole Mounting Procedures

Square Pole Mount

Outlines steps for mounting the fixture on a square pole using the bolster plate and bolt.

Slipfitter Mount Installation

0-10 V Dimmable Wiring

Microwave Motion Sensor Performance

Operating Parameters

Details on voltage, current, output, brightness, detection, and time settings.

Microwave Motion Sensor Lux On-Off Function

Lux On-Off Functionality

Explanation of how the sensor turns lights on/off based on ambient brightness and preset lux levels.

Remote Control Operation

Remote Display and Buttons

Overview of the remote control's display area and button functions.

Overview

This document provides installation, operation, and maintenance instructions for the RAB A17™ Area Light, as well as details for an optional Microwave Motion Sensor (MVS-OD) and its remote control (REMOTE-OD).

A17™ Area Light

Function Description: The RAB A17™ Area Light is a high-quality, affordable, well-designed, and energy-efficient LED lighting fixture. It is designed for easy installation by electricians and aims to help end users save energy. The fixture can be mounted on a universal pole or with a slipfitter.

Important Technical Specifications:

  • Supply Conductors: Minimum 75°C.
  • Voltage: Universal voltage driver permits operation at 120V through 277V, 50 or 60 Hz. Units with a /480 suffix operate at 480V, 50 or 60Hz.
  • Dimming: 0-10V dimmable wiring.
  • Environment: Suitable for wet locations.
  • Pole Drilling Pattern: Accommodates 3 different hole patterns (Hole A must be used, then choose B, C, or D). Measurements for drilling are provided: 0.625" for holes A, B, C, D; 5 1/2" vertical distance from A to D; 3" from A to B; 2" from B to C; 1" from C to D.

Usage Features:

  • Installation:
    • Universal Pole Mount: Involves removing the arm cover, feeding wires, aligning the arm and fixture, tightening internal screws, and replacing the arm cover. For square pole mounting, a bolster plate is placed inside the pole, the round pole adaptor plate is removed, and the arm is fixed with a bolt. For round pole mounting, the bolster plate is placed inside the pole, and the arm is fixed with a bolt. Wires are pulled into the junction box, and supply wires are connected to the arm according to NEC guidelines. Bolts are used to tighten the fixture to the pole.
    • Slipfitter Mount: The slipfitter is placed over a tenon, and the fixture is secured with set screws. Wires are fed through the fixture and slipfitter, and supply wires from the pole are connected. Wires should be knotted for strain relief.
  • Adjustable Angle: The slipfitter mount allows for a 90° adjustable angle. To adjust, loosen the locking bolt and swivel the fixture to the desired angle, using the slipfitter cover plate graduations as guidelines.
  • Wiring (0-10V Dimmable):
    • Black/brown fixture lead to LINE supply lead.
    • White/blue fixture lead to COMMON supply lead.
    • Green/yellow wire from fixture to supply ground (do NOT connect the GROUND of the dimming fixture to the output).
    • Purple fixture lead to DIM V+ lead.
    • Pink fixture lead to DIM V- lead.
  • Safety: Power must be OFF before installation or maintenance. No user-serviceable parts inside. Do not use an electric generator to test LED fixtures. Proper grounding is required. Installation must comply with the National Electrical Code and local codes.

Maintenance Features:

  • Cleaning: Clean the polycarbonate lens with a non-abrasive glass cleaning solution.
  • Restrictions: Do not open the fixture to clean the LED or touch the LED. Do not open or remove the Respirator Plug. Ensure the fixture temperature is cool enough to touch before cleaning or maintenance. Do not clean or maintain while the fixture is energized.

Troubleshooting:

  • Check that the line voltage at the fixture is correct.
  • Verify proper grounding of the fixture.

Microwave Motion Sensor (MVS-OD)

Function Description: The MVS-OD is a microwave motion sensor designed to automatically control the A17™ Area Light based on motion detection and ambient brightness. It can turn lights on/off, dim them, and has various programmable settings.

Important Technical Specifications:

  • Operating Voltage: 12 ± 2V DC
  • Operating Current: 30mA
  • Output: DIM 0-10V
  • Stand-by Power: <0.5W
  • Microwave Frequency: 5.8GHz ± 75MHz
  • Microwave Power: <0.5mW
  • Detection Angle: 30-150°
  • Mounting Height: Max 15M (ceiling mounted)
  • Detection Range: Max Ø15m (ceiling mounted), Max 20m (wall mounted)
  • Operating Temperature: -25°C to +60°C
  • IP Rating: IP65
  • Weight: 0.14lb
  • Dimensions: Approximately 2 1/4" width, 4" height.

Usage Features:

  • Programmable Settings (via Optional Remote - REMOTE-OD):
    • Brightness: 70%, 80%, 90%, 100%
    • Detection Area: 20%, 50%, 75%, 100%
    • Hold Time: 10s, 1min, 10min, 30min
    • Daylight Threshold: 10Lux, 30Lux, 50Lux, 100Lux, Disable
    • Stand-by Period: 1min, 30min, 60min, +∞ (unlimited)
    • Stand-by Dimming Level: 10%, 20%, 30%, 50%
  • Factory Settings:
    • Brightness: 100%
    • Hold Time: 1 Minute
    • Daylight: Disabled
    • Sensitivity: 50%
    • Stand-by Dimming Level: 20%
    • Stand-by Time: 1 Minute
  • Wiring Diagram:
    • Black/White: 12V+
    • Purple: DIM+
    • Pink: 12V-/DIM-
    • L (Line) and N (Neutral) connect to the LED Driver.
  • LUX ON-OFF Function: The sensor automatically turns off the light when ambient brightness exceeds a preset lux level. This function requires the Stand-by period to be +∞ and the Stand-by dimming level to be 10%, 20%, 30%, or 50%. Daylight threshold can be set to 10Lux, 30Lux, 50Lux, or 100Lux.
    • If ambient brightness is lower than preset lux level, the light automatically turns on.
    • If motion is detected while ambient brightness is insufficient, the light dims to 100%.
    • If no motion is detected after the hold time, the light dims to the stand-by level.
    • If ambient brightness is higher than preset lux level, the light automatically turns off.
  • Detection Coverage: Detailed diagrams show ceiling-mounted and wall-mounted detection patterns, indicating "Well Covered" and "Covered" areas.

Remote Control (REMOTE-OD)

Function Description: The REMOTE-OD is an optional remote control used to program the settings of the MVS-OD Microwave Motion Sensor.

Usage Features:

  • Remote Display Area: Shows current settings for Brightness, Daylight, Standby Dim, Hold Time, Sensitivity, and Standby Time.
  • Button Setting Area:
    • ON/OFF: Long press to turn on/off the fixture.
    • BRIGHTNESS: Adjusts dimming level (70%/80%/90%/100%). Factory setting: 100%.
    • SEND: Saves current settings.
    • HOLD TIME: Adjusts hold time (10s/1min/10min/30min). Factory setting: 1 minute.
    • DAYLIGHT: Long press to adjust daylight threshold (10lx/30lx/50lx/100lx). Factory setting: disabled.
    • SENSITIVITY: Adjusts sensitivity (20%/50%/75%/100%). Factory setting: 50%.
    • STANDBY DIM: Adjusts stand-by dimming level (10%/20%/30%/50%). Factory setting: 20%.
    • STANDBY TIME: Adjusts stand-by time (+∞/1min/30min/60min). With Daylight activated, options include unlimited stand-by time (light control, turn on/off based on lux levels) or light threshold mode (light turns on if light level is < preset lux and motion is detected). Factory setting: 1 minute.
    • RESET: Resets all settings to factory defaults (Brightness 70%/Hold time 10s/Sensitivity 20%/Daylight threshold disable/Stand-by dimmer level 10%/Stand-by time +∞). Products with DIP switch will be controlled by DIP switches.
    • TEST: Puts the sensor in test mode (hold time is only 3s).
    • + / -: Increases/decreases brightness (0%-100%).
  • Programming Guidelines:
    • The remote control must be "on" to send settings. The indicator light will go out after 10 seconds of inactivity.
    • Using the "ON/OFF" button disables all other buttons except "ON/OFF," "BRIGHTNESS," and "SEND."
    • Using the "TEST" button disables all other buttons except "TEST," "SENSITIVITY," and "SEND."
    • Every change requires pressing the "SEND" button to save.
    • Due to power supply dimming ratio differences, "BRIGHTNESS" and "STANDBY DIM" percentages may differ from measured power.

RAB A17 Specifications

General IconGeneral
BrandRAB
ModelA17
CategoryOutdoor Light
LanguageEnglish