What to do if keys beep at the Rain Master Pro Max transmitter but no valves turn on at a non Rain Master controller (Model Pro Max-UA)?
- FfrazierdeanNov 22, 2025
If the keys beep at the Pro Max transmitter but no valves turn on at a non Rain Master controller (Model Pro Max-UA), you should: * Check the installation and antenna connections (see Section 3.2, Figure 8 and Figure 9). * Remove the large 37-pin connector from the universal adapter assembly and then re-insert it. * Listen for the Pro Max receiver tone(s) upon re-insertion of the cable: No tone indicates a problem with the 24 Volts AC and common connections; one tone is OK; two tones are also OK (see Section 4.6 Access Code); any other tones indicate you should contact the factory. * Press the AUTO UP key and listen for a confirmation beep at the Pro Max receiver. If there is no beep, contact the factory. * Verify water is ON at the selected stations, ensure field station wiring...