EasyManua.ls Logo

RainFlo RF4 Series - Cleaning the UV Sensor; Operation

Default Icon
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13|Page
Step 11: Replace the o-ring and slide the sleeve back into the reactor following steps 7 and 8
from the installaon secon of the manual.
Cleaning the UV Sensor
Depending on the water quality, the UV sensor may require periodic cleaning. At a minimum,
the UV sensor should be cleaning on an annual basis. The following steps outline a basic cleaning
procedure.
Step 1: If a by-pass assembly is installed, shut the inlet valve o to prevent water ow through
the system. Otherwise, turn o main water inlet valve (and/or turn o the water pump).
Step 2: Disconnect power cord of UV system from electrical outlet.
Step 3: Release water pressure by opening a downstream faucet and then close the outlet
shut-o valve (if any). If there is no outlet shut-o valve, expect water to drain from the system
as the head pressure in the system will cause the water to ow back down.
Step 4: Place something under the reactor to catch any water that may come out of the
reactor during the removal of the UV sensor.
Step 5: Unscrew (counterclockwise) sensor nut from the reactor and pull the sensor slowly out
of the sensor port.
Step 6: Holding the sensor in your hand wipe the at poron (sensor face) of the sensor with
isopropyl alcohol using a clean lint-free cloth.
Step 7: Replace sensor following step 9 from the installaon secon of the manual.
Operaon
UV systems come with a feature laden controller that incorporates both the lamp driver (ballast)
and control features in one water-ght case. Four main controllers are available for the UV
systems (depending on your model). All four models feature a power factor corrected, constant
current lamp driver with a universal power input.
Please Note: While the LED or display screen is red and the buzzer is sounding the water from
the system should NOT be consumed. If any water does pass through the system during this
period, please follow the disinfecon procedure as outlined in this manual before the water is
consumed. For RF4 and RF5 systems, even though they have a visual and audible warning built
into the controller, a green LED or status screen does not necessarily indicate that the water
coming from this system is in fact potable (safe to drink). These systems do not measure the level
of disinfecon; they simply measure the on-ostatus of the lamp. Please have your water
checked for microbiological contaminants on a regular basis.