Preparing for use
R&S
®
QPS Walk2000
21Getting Started 1179.5782.02 ─ 03
During the self-test and calibration, the light at the gate entrance is illuminated
blue. This process takes a few minutes. When calibration is done, the lights at the
gate entrance change their color (usually yellow).
7. Check if the error log is empty.
8. Check if the frame count is increasing continuously.
9. Check the signal strength bar. The signal strength bar should be green and stable
when the gate is empty.
10. Wait for about 5 minutes before you start scanning people.
After that time period, scan someone. While the gate is occupied, the signal bar
should turn red and return to green when the scanned person exits the gate.
Shutting down the R&S QPS Walk2000
Shutting down the system requires the corresponding user rights.
1. Log into the system with an account type that can shut down the system.
2. Enter the "Settings" menu.
3. Select "System Shutdown".
The R&S QPS Walk2000 automatically shuts down all system components (gates,
touchscreen and server).
4. Turn off the main power with the switch on the primary panel (position "O").
5. Disconnect all power cables from the power source.
Startup and shutdown