Operating Instructions RS cure D cure P cure SHERAprint cure 3Decure
15 27
Rapid Shape GmbH DOCR000251
4.1 Installation Safety
DAN GER!
Danger to life due to electric current!
Incorrect connection, insulation faults, foreign objects
(dust, liquid due to inappropriate installation environ-
ment) or lack of grounding can lead to housing parts
being live. There is an imminent danger of electrocution
in the event of contact with live parts
Work on the electrical equipment may only be
carried out by qualified electricians and in
compliance with the relevant safety and VDE
regulations.
Machines with damage to the power cord, in-
sulation or lack of earthing must be disconnected
from the mains immediately. Repairs are to be
made immediately.
Only operate the machine with the mains voltage
specified for the machine.
Only operate the machine with the power supply
unit supplied
The mains plug must be freely accessible at all
times. A complete separation of the machine from
the mains in an emergency by pulling out the
power plug ( Chapter 5).
Keep moisture away from live parts. This may lead
to short circuiting.
4.2 Setting Up
4.2.1 Requirements for the Installation Location
For the smooth functioning of the machine, please note the following
requirements at the installation location:
dust protected room
protection against direct sunlight (window equipped with UV
protection film)
UV-protected exposure
stable base (table)
Internet connection (LAN/WLAN)
The following optional requirements are recommended:
Air conditioned environment
4.2.2 Setting Up the Machine
For setting up the machine please proceed as follows:
1. Prerequisite: The machine has already been unpacked.
Chapter 3.3
2. Lift the machine to the desired installation location and set it
down.