6 | Electrical connection
80.06.083_iCombiPro-iCombiClassic_IM_en-US 65 / 100
Hz Power con-
sumption
(A)
Power (kW) Fuse (A) RCD model
6-2/3 (3 AC 240 V) 50/60 15.5 6.2 16 B
Hz Power con-
sumption
(A)
Power (kW) Fuse (A) RCD model
6-2/3 E (3 AC 240 V) 60 15.5 5.7 20 B
6 half size E (3 AC 240 V) 60 26 10.8 35 B
6 full size E (3 AC 240 V) 60 53.9 22.4 70 B
10 half size E (3 AC 240 V) 60 45.5 18.9 60 B
10 full size E (3 AC 240 V) 60 90 37.4 125 B
20 half size E (3 AC 240 V) 60 89.5 37.2 125 B
20 full size E (3 AC 240 V) 60 163.3 67.9 200 B
iCombi Pro, iCombi Classic Gasgeräte
Hz Power con-
sumption
(A)
Power (kW) Fuse (A) RCD model
6 half size G (1 ph 120 V) 60 5.0 0.6 15 F
10 half size G (1 ph 120 V) 60 7.5 0.9 15 B
20 half size G (1 ph 120 V) 60 10.8 1.3 15 F
Hz Power con-
sumption
(A)
Power (kW) Fuse (A) RCD model
6 half size G (1 ph 208 V) 60 2.9 0.6 15 B
6 full size G (1 ph 208 V) 60 4.3 0.9 15 B
10 half size G (1 ph 208 V) 60 4.3 0.9 15 B
10 full size G (1 ph 208 V) 60 7.2 1.5 15 B
20 half size G (1 ph 208 V) 60 6.3 1.3 15 B
20 full size G (1 ph 208 V) 60 10.6 2.2 15 B
Hz Power con-
sumption
(A)
Power (kW) Fuse (A) RCD model
6 half size G (1 ph 240 V) 50/60 2.5 0.6 15 B
6 full size G (1 ph 240 V) 50/60 3.8 0.9 15 B
10 half size G (1 ph 240 V) 50/60 3.8 0.9 15 B
10 full size G (1 ph 240 V) 50/60 6.3 1.5 15 B