- 49 - V02 en, SCC_WE
Heating/Motor Status Values
Steam 50% 0 or 1 B5 = X°C Start
Steam 100% 0 or 1 B5 = X°C Start
Hot air 50% 0 or 1 B1 = X°C Start
Hot air 100% 0 or 1 B1 = X°C Start
Fan Motor top Speed 1R Actual Speed X rpm Start
Fan Motor top Speed 1L Actual Speed X rpm Start
Fan Motor top Speed 3R Actual Speed X rpm Start
Fan Motor top Speed 3L Actual Speed X rpm Start
Fan Motor bottom Speed 1R Actual Speed X rpm Start
Fan Motor bottom Speed 1L Actual Speed X rpm Start
Fan Motor bottom Speed 3R Actual Speed X rpm Start
Fan Motor bottom Speed 3L Actual Speed X rpm Start
Water/CleanJet Status Values
Solenoid valve filling Y1 0 or 1 Level electrode S2: water or low water Start
SC Pump M4 0 or 1 Level electrode S2: water or low water Start
Solenoid valve quenching Y2 0 or 1 B2 = X°C Start
Solenoid valve moistening Y3 0 or 1 Start
Care valve Y4 + Pump M12 0 or 1 Level electrode S2: water or low water Start
Cleanjet Pump M6 0 or 1 Start
Drain valve motor M7 direction1 0 or 1 End switch S12: 0 or 1 Start
Drain valve motor M7 direction2 0 or 1 End switch S12: 0 or 2 Start
Functional Group Test (open)
The following functional groups can be started: a sucessfull sequence will generate „OK“
Care
CleanJet
Steam generator management
Humidity control
Selftest
Components Status
Loudspeaker T2 0 or 1 Start
Interior light 0 or 1 Start
Display test Start
Ultravent 0 or 1 Start
Gas Burner Status Values
Gas steam blower Max 0 or 1 CO2: XX% Flame current: XX uA RPM:XXXX Start
Gas steam blower Start 0 or 1 CO2: XX% Flame current: XX uA RPM:XXXX Start
Gas steam blower Min 0 or 1 CO2: XX% Flame current: XX uA RPM:XXXX Start
Gas hot air blower top Max 0 or 1 CO2: XX% Flame current: XX uA RPM:XXXX Start
Gas hot air blower top Start 0 or 1 CO2: XX% Flame current: XX uA RPM:XXXX Start
Gas hot air blower top Min 0 or 1 CO2: XX% Flame current: XX uA RPM:XXXX Start
Gas hot air blower bottom Max 0 or 1 CO2: XX% Flame current: XX uA RPM:XXXX Start
Gas hot air blower bottom Start 0 or 1 CO2: XX% Flame current: XX uA RPM:XXXX Start
Gas hot air blower bottom Min 0 or 1 CO2: XX% Flame current: XX uA RPM:XXXX Start
Function test - Content