USER MANUAL
– RAVAS-3200
15
5.4 Error messages
ERROR MESSAGES
Display Meaning Out of error mode
Err01
Err02
Err03
Err04
Err06
Err08
Err09
Err10
Err14
CAL-J
Err98
Err99
----
Err_L
OimL
ntEP
SCALL
ESoFt
EConF
Load cell signal is unstable
Overload on full scale
Gross negative. This action is not allowed
Out of zero range
Input signal too high
Calibration out of range (negative)
Calibration out of range (signal too low)
Calibration count 2nd (3rd) point lower than count 1st (2nd)
point
Setpoint value 2 < setpoint value 1. This is not allowed
Legal for trade version: action not allowed
Calibration point must be higher than previous one
Action only allowed in start-up units
Loadcell signal negative
Pallet truck is out of level (only legal-for-trade version)
Battery of indicator is empty
action not allowed (only legal for trade version)
action not allowed (only legal for trade version)
audit trail number out of range
Wrong combination of rmwares
P96 not set
Automatic
Automatic after removing weight
Automatic
Press any key
Automatic after correcting input
Automatic
Automatic
Automatic
Automatic
When action is intended, remove jumper JP1
( attention: after this action a complete new
calibration and stamping of the system is
necessary )
Automatic
Automatic
Lift up the forks from the ground
Put the pallet truck into horizontal position
Charge the battery pack
automatic
automatic
Contact RAVAS Service department
Contact your dealer