Stove phase general layout
PHASE DESCRIPTION
FINAL CLEANING The stove is in the switch o󰀨 phase and the cooling phase has not
been completed yet.
SWITCH ON The heater pre-heating phase has started and the pellets start to
fall into the grate.
WAITING FOR FLAME The pellets ignite and take advantage of the heat in the intake air
that passes through the incandescent heater tube.
WORK AT MAX P The stove has completed the switch on phase and runs at
maximum set power
ROOM TEMPERATURE
MODULATION
The room temperature set has been reached.
THE GRATE Brazier cleaning phase is active (periodic function).
ECO STOP With Climate Comfort active, the stove switches to automatic
switch-o󰀨 mode when the room temperature set is reached (see
the dedicated section).
START/RESTART WAIT Switch-on is requested but with the stove in cooling phase; once
this condition is met, it restarts automatically.
SWITCH ON RESTART The HOT restart phase is activated.
Functioning is similar to the SWITCH ON phase
HOT SMOKE The maximum fume temperature threshold has been reached.
To facilitate cooling, the stove brings the capacity to a minimum
with ventilation at power level 5, leading to a decrease in fume
temperature.
OFF The stove is off
WAIT FOR PELLETS
OUT OF
When the switch-on request from ECO-STOP mode coincides
with an automatic switch-off condition (from the TIMER), the stove
turns on ensuring total cleaning of the brazier before switching to
FINAL CLEANING.
INFEED SCREW
OVERFLOW
CONDITION: when the pellet setting (set pellets +5) is near the
continuous load condition.
SOLUTION: Set the value back to 0.
GENERIC ALARM The stove is in alarm state; refer to the troubleshooting chapter.