Replacing the Pad Module
As a guideline, it is recommended to replace the pad module every 50000 sheets of
scans (A4, 70 g/m2 or 18 lb.), and it is recommended to replace the feed roller every
300000 sheets of scans (A4, 70 g/m2 or 18 lb.).
Disassembling Procedure
1. Open the panel unit by pulling the panel unit open lever.
2. Remove the pad module by pinching both sides of the pad module and pull it out.
3. Install the new pad module by inserting the tabs on the module onto their slots
on the scanner.