T
Theresa ScottSep 10, 2025
What to do if low tank volume remaining in Raven Farm Equipment?
- Aamanda91Sep 10, 2025
If the tank volume is low, refill the product to continue field applications.
What to do if low tank volume remaining in Raven Farm Equipment?
If the tank volume is low, refill the product to continue field applications.
What to do if I get a Max PSI/Low PSI Code 104 error on my Raven Water Pump?
To address a Raven Water Pump error related to clogged or restricted pump outlet supply lines, low injection pressure, or incorrect tubing size, first check for any blockages in the outlet supply lines and flush the system to remove clogs. Ensure the correct size of injection outlet tubing is being used. Also, verify that all hand valves are open to allow flow. If the issue persists, consider replacing the pressure transducer.
Why is my Raven Water Pump showing Code 107?
If your Raven Water Pump displays Code 107, it could be due to a clogged pump strainer, restrictions in tubing or plumbing, or the chemical being too thick. Clean the pump strainer and check for obstructions in the injection line. Verify the correct size of injection supply tubing is used. If the chemical is too thick, dilute it in the chemical supply tank, as some chemicals are not suitable for direct injection systems.
What does Code 110 mean on my Raven Water Pump?
If your Raven Water Pump is showing error Code 110, it may be due to no power to the pump motor or a pump motor/encoder issue. First, verify that the high current LED on the injection pump node is lit. Then, check the motor and encoder connections, ensuring they are properly seated. If the connections appear solid, return the pump to a local Raven dealer for service.
What does Motor/Encoder Code 105 mean on my Raven Water Pump?
If your Raven Water Pump is displaying error code 105 related to the motor or encoder, it may be due to no power to the pump motor or a pump motor/encoder issue. First, verify that the high current LED on the injection pump node is lit. Then, check the motor and encoder connections, ensuring they are properly seated. If the connections appear solid, return the pump to a local Raven dealer for service.
How to troubleshoot low pump efficiency in Raven Laboratory Equipment?
To troubleshoot low pump efficiency in Raven Laboratory Equipment, check for the following: * Fouled pump check valves * Air leaks on the injection pump inlet plumbing * Air in the chemical * Plugged inlet strainer * Chemical too thick to flow through the pump Additionally, calculate the volume per minute for the application and verify the rate is within the range of the injection pump. Finally, check the flow monitor sensor.
What to do if Raven Laboratory Equipment shows off rate low?
If the Raven Laboratory Equipment displays an off rate that is too low, check for the following: * Fouled pump check valves * Air leaks on the injection pump inlet * Air in the chemical * Plugged inlet strainer * Chemical too thick to flow through the pump Also, calculate the volume per minute for the application and verify that the rate is within the range of the injection pump.
What to do if Raven Laboratory Equipment displays DI high vacuum error?
If the Raven Laboratory Equipment is showing a DI high vacuum error, follow these steps: 1. Disconnect the vacuum switch from the product cable and test for continuity between pins A and C. If the OHM meter reads a short, the switch is good. If it reads open, the vacuum switch is bad. 2. Check for obstructions from the inlet of the tank. Look for debris in the inlet, a plugged filter/strainer, a hand valve turned in the wrong direction, or an obstruction in the outlet of the chemical tank.
What does PSI Error Code 101 mean on my Raven Water Pump?
If your Raven Water Pump is displaying PSI Error Code 101, it indicates that the transducer is out of calibration or is faulty. You should recalibrate the pressure transducer. If the problem persists, replace the pressure transducer.
What could be the reason for Code 105 on my Raven Water Pump?
If your Raven Water Pump shows Code 105, it might be caused by a flow obstruction in the left exhaust valve or a faulty left pressure transducer. Perform a pump calibration test. If the pump does not calibrate properly, remove the left exhaust cartridge and perform pump maintenance to clear obstructions. If the pump calibrates properly, replace the left pressure transducer.
Category | Farm Equipment |
---|---|
ISOBUS Compatibility | Yes |
Display | Touchscreen |
Connectivity | Wi-Fi, Bluetooth |
Battery Life | Up to 10 hours |